How to read your radon test result (pCi/L explained)

Published [object Object] · Updated 2026-11-18 · Sources checked 2026-11-18

The short answer

Find the number in pCi/L. If a first short-term test is 4 pCi/L or higher, EPA says to do a follow-up test. If it is more than 8 pCi/L, do a second short-term test right away. Fix the home if the follow-up confirms 4 pCi/L or more. Between 2 and 4, EPA says to consider fixing.

Step 1: find the number and the unit

Your lab report or monitor shows a radon concentration, usually in pCi/L (picocuries per liter). Some devices also show Bq/m³. EPA gives 4 pCi/L as equal to 150 Bq/m³, and 2 pCi/L as about 75 Bq/m³ (EPA).

Also note:

Step 2: compare it with EPA's guidance

Result What EPA recommends
4 pCi/L or higher Fix the home, after confirming with a follow-up test (see Step 3)
2 to 4 pCi/L Consider fixing
Below 2 pCi/L No action level is triggered, but CDC says there is "no known safe level," so lower is always better

For context, EPA estimates the average indoor level is about 1.3 pCi/L, and outdoor air is about 0.4 pCi/L (EPA Citizen's Guide).

Step 3: follow up the way EPA describes

EPA's Citizen's Guide lays out these steps:

  1. Take a short-term test. If the result is 4 pCi/L or higher, do a follow-up test.
  2. Follow up with either:
    • a long-term test, which better reflects your year-round average, or
    • a second short-term test, if you need results quickly. EPA notes that the higher your first result, the more reason to use a short-term follow-up. If the first result is more than twice the 4 pCi/L action level (over 8 pCi/L), take a second short-term test immediately.
  3. Decide:
    • After a long-term follow-up: fix the home if the result is 4 pCi/L or more.
    • After a second short-term test: consider fixing if the average of the two tests is 4 pCi/L or more.

Home sales use slightly different, faster rules. See Radon when buying or selling a home.

Why two tests can disagree

Radon levels naturally change from day to day and season to season. Pennsylvania DEP explains that short-term tests are accurate for the time they were running. But the closer a result is to 4 pCi/L, the harder it is to tell whether your year-round average is above or below it. DEP suggests a long-term test (at least 91 days, preferably a year) for short-term results between 4 and 10 pCi/L (PA DEP fact sheet).

Step 4: retest on a schedule

Pennsylvania DEP recommends retesting every two years if the home has a mitigation system, every five years otherwise, and again after renovations or additions (PA DEP). Always retest after a system is installed to confirm it worked (CDC).

Next steps

Frequently asked questions

What does pCi/L mean?

Picocuries per liter of air, the U.S. unit for radon concentration. EPA gives 4 pCi/L as equal to 150 becquerels per cubic meter (Bq/m3), the unit used in many other countries.

My first test was 4.5 pCi/L. Do I need mitigation?

EPA's Citizen's Guide says to follow up a first short-term result of 4 pCi/L or higher with a long-term test or a second short-term test, then fix the home if the long-term result, or the average of the two short-term tests, is 4 pCi/L or more.

What is a normal radon level?

EPA's Citizen's Guide estimates the average indoor radon level at about 1.3 pCi/L, with about 0.4 pCi/L normally found in outdoor air.

How often should I retest?

Pennsylvania DEP recommends testing every two years after mitigation, every five years otherwise, and again after renovations or additions.

Sources

  1. A Citizen's Guide to Radon (EPA 402/K-12/002), U.S. EPA (2016).
  2. EPA Map of Radon Zones (action level and unit conversions), U.S. EPA.
  3. Radon and Your Health, CDC (June 18, 2026).
  4. Radon and Testing fact sheet (2940-FS-DEP4428), Pennsylvania DEP.

This guide is for general information only. It is not medical, legal, or engineering advice. Read our disclaimer.